Loading...
HomeMy WebLinkAboutCity of Tamarac Ordinance O-1978-019Temp. #523 2/7/78 Introduced by: C/?yz _ Rev. 2/14/78 (C/M K) Rev. 2/27/78 (C/M D) Rev. 3/1/78 Rev. 4/12/78 (C/M D) CITY OF TAMARAC, FLORIDA ORDINANCE NO. AN ORDINANCE OF THE CITY OF TAMARAC, REPEALING SECTIONS 6-26 and 6-27 OF ART. III OF CHAPTER 6 AND AMENDING CHAPTER 7, BY ADDING THERETO DIVISION 3, SECTION 7-30, DUMPSTERS, RELATING TO THE STANDARDS FOR THE LOCATION AND CONSTRUCTION OF TRASH ENCLOSURES; AND AMENDING CHAPTER VII BY ADDING THERETO DIVISION 4, SECTION 7-31, ROOFSCAPES, ESTABLISHING STANDARDS FOR CONCEALING MECHANICAL EQUIPMENT ON ROOF TOPS IN ALL ZONING DISTRICTS: PROVIDING AN EFFECTIVE DATE. NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF TAMARAC, FLORIDA: SECTION 1: Chapter 6, Beautification, Article III, Section 6-26 and 6-27 of the Code of the City of Tamarac, are hereby repealed. SECTION 2: Chapter 7, Building, is hereby amended by adding thereto a new Division 3, Section 7-30, of the Code of the City of Tamarac, to read as follows: SECTION 7-30: DUMPSTER REQUIREMENTS (1) All bulk containers required by the Broward County Code of Ordinances relating to the collection and disposal of garbage shall be designed, constructed, and maintained in conformance with the following standards and criteria. (2) The Petitioner's responsibility to demonstrate compliance with the aforesaid shall be required prior to receiving approval of either a preliminary site development plan, requesting a final building inspection, certificate of occupancy. (3) The owner and/or tenant shall submit to the Chief Building Official proof of a contract for collection of trash and garbage with a collector franchised in the City prior to requesting any certificate of occupancy or occupational license in a format avail- able in the Office of the City Clerk. (4) Construction and Location Standards: All exterior trash enclosures in new developments or requested revisions in existing developments, or upon request for a new or renewed occupational license involving the retail or wholesale consumption, manufacturing, sale or storage of food or food products shall be required to comply with the following standards: (a) It is the responsibility of the proposed user to identify the number, size and material of all trash containers and enclosures, either known or generally estimated, on the Preliminary Site Development Plans submitted to Tamarac for development or building permits. (b) All trash receptacles shall be required to be shielded by solid masonry walls (stuccoed and painted) and solid gates. (c) The height of the walls and gates shall be as follows: Up to 6 cu yd. container ---- 6' high Up to 8 cu yd. container ---- 8' high (d) The minimum inside dimensions of the enclosure shall be three (3) feet wider than the width of the receptacle and two (2) feat deeper than the depth. If the size of the receptacle is unknown, then the minimum size of a proposed enclosure shall be no less than 10' by 10' (inside dimensions) with 6' high walls. (e) The gates of the enclosure shall have no panel wider than 6' and be constructed of a material of sufficient strength to withstand normal daily use of rubbish disposal and pickup. Chain link gates with slats are not permitted. Solid metal posts shall be placed in front of the gate hinges. However, hinges may be attached to the posts. (f) The base of the enclosure is to be concrete with a minimum of 4" in depth. (g) SETBACKS: The enclosures shall be permitted to encroach into the side and rear setbacks up to three (3) feet from the property line when the abutting property is zoned B-1, B-2, B-3 or M-1. When the enclosure is placed adjacent to property lines abutting all other districts, the setbacks shall be the same dimensions as for the principal buildings. (h) All dumpsters located within a building shall be in trash rooms provided with an automatic sprinkler, washing facilities and deodorizing system. 1 1 (i) The trash receptacles and enclosure shall be located in a position convenient to pickup by front-end and back -end loaders. SECTION 3: Chapter 7,' Building, is hereby amended by adding thereto a new Division 4, Section 7-31 of the Code of the City of Tamarac to read as follows: SECTION 7-31 -- ROOFSCAPES The height of exterior perimeter walls of all buildings in all zoning districts except R-1, R-1B, R-IC and R-2 shall be higher than the total height of all accessory equipment installed on the roof of the proposed building. All air conditioning units, condensers, and/or electrical fans attendant thereto shall be prohibited from being installed on all residential and accessory roof areas in R-1, R-IB, R-1C and R-2 zoning districts, unless the same shall meet the following requirements: 1. The proposed air conditioning unit shall be placed on a structural element meeting the requirements of the South Florida Building Code, Broward Edition. 2. The proposed plans accompanied by fee, shall be submitted to and approved by the Tamarac Building Department. 3. Permanent, obscure screen shall be placed along all sides of the unit which is viewed by the public, the minimum height of which shall be one foot above the top of the unit. SECTION 4: Severability Clause: Should any section or provision of this Ordinance or any portion hereof, or any paragraph, sentence, or word be declared by a court of com- petent jurisdiction to be invalid, such decision shall not affect the validity of the remainder hereof as a whole or any part hereof, other than the part to be declared invalid. -3- L.1 n 1 SECTION 5: Conflict: All Ordinances or parts of Ordinances in conflict herewith be and the same are hereby repealed, as of the effective date of this Ordinance. SECTION 6: Effective Date: This Ordinance shall take effect immediately upon its final passage. PASSED FIRST READING THIS DAY OF . 1978. PASSED SECOND READING THIS /-Z DAY OF , 1978. ATTEST: W—Ve" Wi. 90 I HEREBY CERTIFY THAT l have approved the form and correct- ness of this Ordinance. CITY TTORN me RECORD OF COUNCIL VOTE MAYOR W. FALCK V/M H. MASSARO rA we C/M I. M. O1SR4[L13'__-_. C/M M. KLKA RECORD OF COUNCIL VOTE MAYOR W. FALCK V/M H. MASSARO C/M I. M. 01SRW :. _... Q.ua