Loading...
HomeMy WebLinkAboutCity of Tamarac Ordinance O-1978-035' 89 Introduced byTemp. # 4 1 2 3 !,E 51 6 7 8 9 10 1.1 12 13 14 15 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 CITY OF TAMARAC, FLORIDA ORDINANCE NO. 0-- 7(f- 3Z-- AN ORDINANCE AMENDING SECTION 24.17 OF THE TAMARAC CITY CODE AS AMENDED BY ORDINANCE NO. 76-40 AND BY ORDINANCE 78-21 WHICH PERTAINS TO THE DESIGN OF STORM DRAINAGE SYSTEMS; PROVIDING FOR CODIFICATION; PROVIDING FOR SEVERABILITY; PROVIDING A REPEALER; AND PRO- VIDING AN EFFECTIVE DATE. BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF TAMARAC, FLORIDA: SECTION 1: That Section 24.17 of the Tamarac City Code as amended by Ordinance No. 76--40 and later amended by Ordinance 78-21 is amended by deleting the words indicated below in struck through type as follows: uw__i____ nn I� M r r rn Kl Al ["TA nRA nn/1 TRl A nr ['\/C T P'KA The storm drainage system required for land develop- ment shall be designed in accordance with the engineering principles accepted by the Florida State Department of Transportation and in conformance with the following design criteria: (a) Rational formula (Q = c i A) shall be used. (b) Coefficient of runoff shall be 0.95 for impervious areas and from 0.5 to 0.9 for grassed areas. (c) Storm drainage shall be designed by outlet control methods to the effect that a ten year design storm will produce a headwater no higher than the lowest catch basin rim and a twenty-five year storm will produce a headwater no higher than 1 inch below the center line crown of the roadway or the inside edge of the roadway on roadways with medians, The minimum gutter and pavement gradient shall be .003-feet per foot. (d) Manning's "n" shall be 0.013 for reinforced con- crete or fully paved or lined corrugated metal pipe; 0.019 for unpaved, helically corrugated aluminum pipe and 0.024 for unpaved, unlined, annularly corrugated pipe. 1 2 3 4 7 8 9 10 2.2. 12 13 14 15 16 20 21 22 23 24 25 2E 27 28 29 30 31 91FA 33 34 (e) Design water level of the secondary canals into which the outfall pipes flow shall be +7.00 feet MSL for systems in the C-14 drainage basin and +6.00 feet MSL for those systems discharging into the C-13 basin. The developer's engineer shall submit a copy of his design calculations to the City Engineer for his approval. The City Engineer may permit other design criteria to be used or may require the developer's designer to use criteria other than those given in this section, fie-eel-leas-thae-gene esiya��sf�e�- }e-tbs-wei }ep, which the City Council may deem nec- essary for the health, safety and welfare of the public. Inlets, catch basins, manholes, headwalls and other drainage structures shall be of a design approved by the City Engineer." SECTION 2: codify this Ordinance. C.iWT Adrsl�kl ew Specific authority is hereby granted to Should any section or provision of this Ordinance or any portion hereof or any paragraph, sentence or word be declared by a Court of competent jurisdiction to be invalid, such decision shall not affect the validity of the remainder hereof as a whole or any part hereof other than the part declared to be invalid. SECTION 4: All ordinances or parts of ordinances in conflict herewith are repealed to the extent of such conflict. SECTION 5: This ordinance shall become effective immediately upon its passage at First and Second reading. PASSED FIRST READING THIS eel, DAY OF ,1978. PASSED SECOND READING THIS DAY OF ,1978. ATTEST: MAYOR L :CITY CLEIRK RHOD OF CNINCIL "VOTE I HEREBY CERTIFY THAT I have approved theMAYUR W_FALCK form and correct ess of this ORDINANCE V,'MH.MASSARU,_Ole- � , C/M H. WIENER _....�._ �-- ARTHUR M. BIR EN, CITY ATTORNEY C/MIN, DISRAELLY_62le G!M 1,t KLIKA e-10 M I�tLc� sA,117? 6111y/-7F