Loading...
HomeMy WebLinkAboutCity of Tamarac Ordinance O-2004-031Temp. Ordinance #2048 Page 1 August 11, 2004 Revision #1 — August 31, 2004 Revision #2 — September 1, 2004 Revision #3 — September 23, 2004 CITY OF TAMARAC, FLORIDA ORDINANCE NO. 0-2004- 3 AN ORDINANCE OF THE CITY COMMISSION OF THE CITY OF TAMARAC, FLORIDA, AMENDING CHAPTER 10 OF THE CITY CODE ENTITLED, "LAND DEVELOPMENT REGULATIONS", ARTICLE IV, "STANDARDS AND CRITERIA", SECTION 10-128, "FIRE PROTECTION", DELETING SECTIONS OF THE CITY CODE IN CONFLICT WITH THE FLORIDA FIRE PREVENTION CODE; PROVIDING FOR CODIFICATION; PROVIDING FOR CONFLICTS; PROVIDING FOR SEVERABILITY; AND PROVIDING FOR AN EFFECTIVE DATE. WHEREAS, the Tamarac Fire Rescue Department currently provides fire and rescue services to the residents and businesses of the City; and WHEREAS, the State of Florida adopted the Florida Fire Prevention Code effective January 1, 2002; and WHEREAS, the Florida Fire Prevention Code supersedes Tamarac City Code; and WHEREAS, current City of Tamarac Code requirements are in conflict with the Florida Fire Prevention Code; and WHEREAS, Section 10-28 of the City Code provides that fire protection service shall be adequate to protect the people of the City of Tamarac; and Coding: Words in strueli thFeugh are deletions from existing law; Words in underscored type are additions. Temp. Ordinance #2048 Page 2 August 11, 2004 Revision #1 — August 31, 2004 Revision #2 — September 1, 2004 Revision #3 — September 23, 2004 WHEREAS, the City Commission of the City of Tamarac deems it to be in the best interest of the citizens and residents of the City of Tamarac to amend Section 10-128 of the City Code to conform to the Florida Fire Prevention Code. NOW, THEREFORE, BE IT ORDAINED BY THE CITY COMMISSION OF THE CITY OF TAMARAC, FLORIDA: SECTION 1: That the foregoing whereas clauses are hereby ratified and confirmed as being true and correct and are hereby made a specific part of this Ordinance upon adoption hereof. SECTION 2: That Chapter 10 of the Tamarac City Code entitled, "Land Development Regulations", Article IV, "Standards and Criteria", Section 10-128, "Fire Protection", is hereby amended as follows: Section 10-128. Fire Protection. Fire protection service shall be adequate to protect people and property in the proposed development. The standards to be applied shall be: (1) Water supply. Water supply facilities either existing or proposed to be constructed by the developer shall be adequate to meet the fire protection needs and shall be installed prior to the issuance of any building permit other than for models for the proposed development to meet the fire protection needs for the development. All existing and proposed developments shall have available a public fire protection water supply system. The supply shall include fire hydrants as shown on the approved final site plan, and engineering drawings and required main sizes shall be determined by computing fire flows in accordance with the Guide for Determination of Required Fire Flow as published by the Insurance Services Office as may be amended. A permanent fire protection water supply system shall be functional prior to the issuance of the final certificate of occupancy. Coding: Words in struel( through are deletions from existing law; Words in underscored type are additions. Temp. Ordinance #2048 Page 3 August 11, 2004 Revision #1 — August 31, 2004 Revision #2 — September 1, 2004 Revision #3 — September 23, 2004 (2) Fire hydrants. Fire hydrants, where required, shall be installed according to the approved final site plan, with the following requirements: (a) For residential projects, fire hydrants shall be placed on lines six (6) inches or larger in diameter and shall be spaced so that the furthest portion of all principal buildings, divisions thereof, or dwelling units therein, and all building areas of site plan and parcels are within three hundred (300) feet of a hydrant as a fire hose is normally deployed. (b) For all other types of development other than residential, fire hydrants shall be placed on water lines either (8) inches or larger in diameter and shall be placed so that a hydrant is no closer than forty (40) feet from a building and no further than two hundred (200) feet from any exterior portion of all principal buildings. The commission may waive these requirements based on the recommendation of the fire chief or the chief's designee and the level of fire protection in the building. (c) In the case of a building which contains standpipe or sprinkler systems, or both, a fire hydrant shall be installed within fifty (50) feet o , with on a minimum main size of eight (8) inches in diameter. SECTION 3: It is the intention of the City Commission and it is hereby ordained that the provisions of this Section shall become effective and be made a part of the Code of Ordinances of the City of Tamarac, Florida, and that the Sections of this Ordinance may be renumbered, relettered and the word "Ordinance" may be changed to "Section", "Article" or such other word or phrase in order to accomplish such intention. SECTION 4: All Ordinances or parts of Ordinances, and all Resolutions and parts of Resolutions in conflict herewith are hereby repealed to the extent of such conflict. Coding: Words in struek thmugh are deletions from existing law; Words in underscored type are additions. SECTION 5: If any provision of this Ordinance Temp. Ordinance #2048 Page 4 August 11, 2004 Revision #1 — August 31, 2004 Revision #2 — September 1, 2004 Revision #3 — September 23, 2004 or the application thereof to any person or circumstance is held invalid, such invalidity shall not affect other provisions or applications of this Ordinance that can be given effect without the invalid provision or application, and to this end the provisions of this Ordinance are declared to be severable. SECTION C: This Ordinance shall become effective immediately upon its passage and adoption. PASSED, FIRST READING this 27t" day of October, 2004. PASSED, SECOND READING this 10t" day of November, 2004. ATTEST: MARION SW NSON, CMC CITY CLERK I HEREBY CERTIFY that I have approved this ORDINANCE as to form. MITCMELL CITY ATT J E SCHREIBER MAYOR RECORD OF COMMISSION VOTE: 1st Reading MAYOR SCHREIBER Ale- DIST 1: COMM. PORTN R A4 6 _ DIST 2: COMM. FLANSBAUM-TALABISCO DIST 3: V/M SULTANOF DIST 4: COMM. ROBERTS btienf RECORD OF COMMISSION VOTE: 2nd Reading MAYOR SCHREIBER A\1P_ DIST 1: COMM. PORTNER DIST 2: COMM. FLANSBAUM- ALABISCO , DIST 3: V/M SULTANOF DIST 4: COMM. ROBERTS Coding: Words in :otter are deletions from existing law; Words in underscored type are additions. 1 1 1