Loading...
HomeMy WebLinkAboutCity of Tamarac Resolution R-2001-145Temp. Reso. #9356 April 12, 2001 1 CITY OF TAMARAC RESOLUTION NO. R-2001- I�l� A RESOLUTION OF THE CITY COMMISSION OF THE CITY OF TAMARAC, FLORIDA, TO RECEIVE THE FISCAL YEAR 2000 CITY OF TAMARAC WATER AND WASTEWATER SYSTEM ANNUAL REPORT PREPARED BY THE CITY'S CONSULTING ENGINEERS, HARTMAN & ASSOCIATES, INC., ON BEHALF OF THE CITY OF TAMARAC'S UTILITIES DEPARTMENT AS REQUIRED BY BOND COVENANTS FOR CONTINUING DISCLOSURE FOR THE TAXABLE WATER AND SEWER UTILITY REVENUE REFUNDING BONDS SERIES 1996 AND REFUNDING BONDS SERIES 1992; PROVIDING FOR CONFLICTS; PROVIDING FOR SEVERABILITY; AND PROVIDING FOR AN EFFECTIVE DATE. WHEREAS, the City of Tamarac has covenanted for the benefit of the Series 1992 and Series 1996 bondholders through continuing disclosure to provide certain financial information and operating data relating to the City by not later than April 1 in each year; and WHEREAS, the City's of Tamarac's Bond Resolution Nos. R-95-296 and R-85-436 require that the Consulting Engineers for the Utilities Department review the operation, maintenance and repair of the City's water and wastewater facilities, and to report annually to the City with their recommendations and comments as to the water and wastewater systems; and Temp. Reso. #9356 April 12, 2001 2 WHEREAS, the City's Consulting Engineers, Hartman & Associates, Inc., have prepared the Fiscal Year 2000 Water and Wastewater System Annual Report (attached hereto as "Exhibit 1") which addresses the sufficiency of the water and wastewater system rates and charges, the operations and maintenance of the water and wastewater systems, and the status of compliance with covenants and agreements contained in the Bond Resolution; and WHEREAS, Hartman & Associates, Inc., have concluded that the Utilities Department has performed the necessary operation and maintenance activities to keep the facilities in proper condition and that the planned capital activities are adequate to meet the anticipated growth of the City's service area; and WHEREAS, Hartman and Associates, Inc. concluded that water and wastewater rates were sufficient to maintain the continued operations of the Utilities Department in Fiscal Year 2001; and WHEREAS, it is the recommendation of the Director of Utilities that the City Commission receive the Fiscal Year 2000 City of Tamarac Water and Wastewater Systems Annual Report; and WHEREAS, the City Commission of the City of Tamarac, Florida deems it to be in the best interest of the citizens and residents of the City of Tamarac that Temp. Reso. #9356 April 12, 2001 3 1 they receive the Fiscal Year 2000 City of Tamarac Water and Wastewater System Annual Report as prepared by Hartman and Associates, Inc. NOW, THEREFORE, BE IT RESOLVED BY THE CITY COMMISSION OF THE CITY OF TAMARAC, FLORIDA THAT: SECTION 1: The foregoing "WHEREAS" clauses are hereby ratified and confirmed as being true and correct and are hereby made a specific part of this resolution. SECTION 2: The Fiscal Year 2000 City of Tamarac Water and Wastewater System Annual Report as prepared by the City's Consulting Engineers, Hartman & Associates, Inc. (a copy of which attached hereto as "Exhibit 1 "), be received. SECTION 3: All Resolutions or parts of Resolutions in conflict herewith are hereby repealed to the extent of such conflict. SECTION 4: If any clause, section, other part or application of this Resolution is held by any court of competent jurisdiction to be unconstitutional or invalid, in part or application, it shall not affect the validity of the remaining portions or applications of this Resolution. Temp. Reso. #9356 April 12, 2001 4 SECTION 5: This Resolution shall become effective immediately upon its passage and adoption. PASSED, ADOPTED AND APPROVED this 13 day of JUYL - 1►111111111 ATTEST: RION SWENSON CITY CLERK I HER BY CERTIFY that I have Appr v this RES��TION to form N � MITCHEWS. H CITY ATTOR KW/db JO SCHREIBER �' MAYOR RECORD OF COMMISSION MAYOR SCHRIEBER DIST 1: COMM. PORTNER DIST 2: COMM. MISHKIN _ DIST 3: V/M SULTANOF _ DIST 4: COMM. ROBERTS J No Text City of Tamarac Water and Wastewater Systems Annual Report Fiscal Year 2000 Prepared for: City of Tamarac Utility Department Prepared by: Hartman & Associates, Inc. 8211 West Broward Blvd., Suite 330 Plantation, Florida 33324 April 12, 2001 CITY OF TAMARAC WATER AND WASTEWATER SYSTEMS 2000 ANNUAL REPORT TABLE OF CONTENTS Section Title Page Executive Summary 1 1 Background/System Summary 3 2 Utility Organization 8 3 Ongoing Maintenance, Renewal and Replacement 11 Improvements, and Depreciation 4 Rate Sufficiency and Debt Service Coverage 20 Appendix 1 Maintenance Record Schedule i MAG/jm/NewServer/WordProc 1996/96-108.21 /Reports 4/ 12/01 11 IEXECUTIVE SUMMARY BACKGROUND ' The Fiscal Year 2000, Annual Report was prepared to address the requirements of the covenants and bond restrictions found in the 1996 series Taxable Water and Sewer Revenue Refunding Bonds. Consequently, this document reports on the sufficiency of rates and charges for services, determines whether the level of maintenance is adequate ' and reviews the adequacy of the renewal and replacement program and other capital funding for fiscal 2001. ' Data supplied by The City of Tamarac (The City) was analyzed to determine the Utility's progress on complying with the covenants of the Bond Issues. Data considered included ' the end of Fiscal Year 1999 reserve balances, the customer base, the water and wastewater consumed and billed, the water and wastewater rates and charges, the fiscal ' year 2001 budget, the capital improvement program (CIP) debt service coverage, and the level of renewal and replacement funding. ' AWARDS ' As an indication of the City of Tamarac's commitment to operation and maintenance of their utility system, the Florida Department of Environmental Protection (FDEP) presented the City of Tamarac one of 17 awards for Plant Operations Excellence. The annual ceremony is a way for the FDEP to recognize public drinking water and domestic wastewater facilities who demonstrate excellence in operation, maintenance, innovative treatment, waste reduction and pollution prevention, conservation, recycling, 1 and other special achievements. ' Criteria used in selecting include: compliance history for the last two years, record keeping and reporting, customer relations, outstanding operation and maintenance practices, and facility operation which includes staff training and safety equipment ' training. Through these awards, the department recognizes each facility's commitment to excellence in management through dedicated professionalism. I MAG/jm/Newserver/WordPr0c/1996/96-108.21 /Reports 4/ 1 zoo 1 1 1 1 u 1 1-1 1 Ll 1 1 I SECTION I - BACKGROUND/SYSTEM SUMMARY 11 SECTION 1 BACKGROUND/SYSTEM SUMMARY PURPOSE The purpose of this document is to provide the City of Tamarac with an annual report as required by the covenants of the City's Taxable Water and Sewer Revenue Refunding Bonds, Series 1996. The document provides information on the Utility Department's organizational structure and funding. The report also contains information about ongoing maintenance and new improvements to the City's water and wastewater facilities. Additionally, the report reviews proposed capital funding, especially renewal and replacement funding and evaluates sufficiency of the existing rates and charges. BACKGROUND The City of Tamarac was incorporated in 1963, by the State of Florida Legislature and occupies an area of approximately 11.6 square miles in the northwestern portion of Broward County. The City is primarily a residential community with easy access to nearby areas of industry, commerce, and recreation. Fixed Assets The City of Tamarac Utility system has fixed assets estimated to be worth sixty-three million four hundred and seventy-seven thousand dollars ($63,477,000). Major fixed assets include the water treatment facilities and equipment, the water distribution system, the wastewater collection and transmission system, computers, trucks, meters and other property. Depreciation of the fixed assets can be used to roughly approximate the money needed for future capital expenses. Ordinances and Resolutions Ordinances. The City passed Temporary Ordinance Number 1768 consolidating the East and West Utility service areas into one Utility in 1996. The ordinance was passed to MAG/jmNewServer/WordProc//1996/96-108.21/R"Tts 3 4/12/01 1 1-1 F F1 allow the Utility service areas to benefit from economy of scale, thereby minimizing a rate increase. Rate resolutions. In 1996, the City passed Resolution R-96-212 establishing uniform rates for the East and West service areas. In 1998, the City passed Resolution No. R-98- 136, modifying Resolution No. R-96-212 by raising the Cost In Aid of Construction (CIAC) charges for Water and Wastewater. Bond resolutions and debt service. Bond Resolution Nos. R-95-296 and R-85-436 are the City resolutions that were passed to issue the current Taxable Water and Sewer Utility Revenue Refunding Bonds. The total debt is approximately seventeen million dollars ($17,000,000). Water and Wastewater Service Area The City of Tamarac's water and wastewater service area is approximately 11.4 square miles of urbanized residential, commercial, and industrial land uses. The service area is approximately 94% built -out. The City Planning Department estimates that projected development will fill in the remaining land by the year 2005. Most of the service area (10.67 mil) is West of S. R. 7 (U. S. HWY. 441). Existing Water Treatment Facilities The City's existing water treatment plant (WTP) facility is located one block west of the northwest corner of the intersection of University Drive and NW 61 st Street within the corporate city limits. The existing treatment process consists of raw water supply wells, pre -chlorination, lime softening, chlorination, polymer addition and rapid sand filtration, and fluoridation. The raw water production facilities consist of 19 water supply wells. Six (6) of the wells are located at the WTP site, and three (3) of the wells are located adjacent to the WTP site. Two (2) additional wells were completed in 1996, to the South of the WTP. Eight (8) remote wells are located approximately 0.3 miles due East of the WTP. All of the raw water wells are controlled from the main control console in the WTP. The South Florida Water Management District renewed the City's Water Use Permit in March 1999. The City is allocated an average 7.54 million gallons per day (MGD) or 2,754 million gallons per year through the year 2004. MAG/jmNewSmer/WorVroc//1996/96-108,21/R"Tts 4 4/12/01 11 Lime softening of the water is provided by three (3) steel water softening units (accelators) including two (2) with a capacity of 8 million gallons per day (MGD) and one with a capacity of 4 MGD. The two 8 MGD accelators are alternated every six (6) months as the duty unit, and the 4 MGD accelator serves as the standby unit. The WTP has a design capacity of 20 MGD. The plant currently produces an average daily flow (ADF) of 5.7 MGD of finished water. The permitted capacity of the WTP is 20 MGD. Softened water is fed from the accelator(s) to six steel rectangular dual -media gravity filters, each with three cells, or to the single 8-MGD automatic filter with four cells. The 8 MGD filter was placed into operation during fiscal year 1989. These filters are periodically backwashed (manually for the rectangular gravity filters and automatically or manually for the 8 MGD filter) for the removal of residual solids in the media. Backwash and blow off water is routed to an onsite lime pond. Finished filtered water is piped to the clear well. Finished water may be pumped directly into the distribution system from the clear well, or may be transferred to the one million gallon onsite storage tank or the two remote storage tanks, and repumped into the system from there. Existing Water Distribution System Water is distributed throughout the City's service area in over 229.5 miles of water mains ranging in size from 2 to 30 inches in diameter. In addition, there are two storage/booster pump stations located within the distribution system. Remote Storage Tanks and Booster Pumping. The storage and booster pump stations in the water distribution system are the Grant's Plaza and Tract 27 booster stations, respectively. The City plans to construct a 2 million gallon ground storage tank at the WTP site. Grant's Plaza Station: The Grant's Plaza Station consists of a one million gallon ground level storage tank, and is equipped with two 1,500 gallon per minute (gpm) booster pumps. The facility is located near the corner of Commercial Boulevard and U.S. Hwy, 441. Tract 27 Station: The Tract 27 station consists of a two million gallon ground level storage tank, and is equipped with two 3,000 gpm and one 1,500 gpm MAG/jmNewServer/WordProe//1996/96-109.21/Reports 5 4/12/01 11 booster pumps. The facility is located near the corner of NW 100th Avenue and 77th Street. These stations, along with on -site storage at the WTP, have a combined storage of four million gallons (which will be increased to 6.0 MG with the completion of the new 2.0 MG tank at the WTP). Both the Grant's Plaza and Tract 27 stations are connected to the telemetry system, so they can be monitored and controlled from the WTP. Emergency Interconnections. The City has 7 (seven) emergency interconnects with Broward County, the City of Lauderhill, the City of North Lauderdale, and the City of Coral Springs. Existing Wastewater Collection, Treatment and Disposal Facilities The City abandoned its WWTP in 1988, when it signed a Large User Wastewater (LUW) Agreement with Broward County. The City of Tamarac's wastewater system is in the North region of the Broward County Wastewater Service Area. The City agreed to purchase wastewater transmission, treatment and disposal services from Broward County at the North Regional Wastewater Treatment Plant (WWTP). The City is required to construct, operate, and properly maintain, all necessary sanitary gravity sewers, lift stations, pumping stations, force mains, and other required appurtenances related and directly attributable to the wastewater collection system upstream of the point of connection to Broward County's Wastewater system. Broward County provides wastewater transmission, treatment and disposal service to the City at fees, rates, and charges constituting the full cost of such service. The City currently reserves 8.04 MGD of capacity at the Broward County plant Flows from the local collection system are routed to two Broward County regional pumping stations. These stations pump wastewater from the City into Broward County's regional wastewater transmission system. The wastewater is then conveyed to Broward County's North Regional Wastewater Treatment Plant in Pompano Beach. These two regional pump stations are owned, operated and maintained by the Broward County Office of Environmental Services. In addition to Broward County, the City of Tamarac has had a large user agreement with the City of Fort Lauderdale since 1981 to service the eastern portion of the City, formally MAG/jmNewSmer/WordProc//1996/96-108.21/Reports 6 4/12✓01 11 known as Tamarac East Utilities. The contracted for flow with Fort Lauderdale is 0.165 MGD. Wastewater pump stations. The City of Tamarac's wastewater system also includes 74 sewage -pumping stations. The majority of these stations serves small areas and is minor in size, with pumping capacities ranging from 75 to 1000 gallons per minute (gpm). Some of these pumping stations are currently monitored by a radio -based telemetry system. The City will complete the design of a radio -based telemetry system that will monitor all the pumping stations during FY01. The monitoring system is located in the WTP building which serves as the master control station of the wastewater pumping station network. 2000 Plant Operations Excellence Award As an indication of the City of Tamarac's commitment to operation and maintenance of their utility system, the Florida Department of Environmental Protection (FDEP) presented the City of Tamarac one of 17 awards for Plant Operations Excellence. The annual ceremony is a way for the FDEP to recognize public drinking water and domestic wastewater facilities who demonstrate excellence in operation, maintenance, innovative treatment, waste reduction and pollution prevention, conservation, recycling, and other special achievements. Criteria used in selecting include: compliance history for the last two years, record keeping and reporting, customer relations, outstanding operation and maintenance practices, and facility operation which includes staff training and safety equipment training. Through these awards, the department recognizes each facility's commitment to excellence in management through dedicated professionalism. MAG/jmNewServer/WordProc//1996/96-108.21/Reports 7 4/12/01 1 1 1 1 1 1 1 1 SECTION 2 - UTILITY ORGANIZATION 1 11 SECTION 2 UTILITY ORGANIZATION GENERAL ORGANIZATION The Utility Department is currently organized into five (5) divisions grouped by function. The Utility Department's organizational chart is shown at the end of this section. Funding for the Utility Department is derived from user fees (Utility Fund), and the State permitted Contribution in Aid of Construction (CIAC) charge paid by developers. For the purposes of this Report, it can be assumed that all operation and maintenance costs are taken from the Utility Fund. The CIAC monies are used to finance growth related Capital Improvement projects. The Department's mission statement is as follows: "To provide excellent and cost-effective service to the residences and businesses of the City of Tamarac through the operation of systems that provide an adequate supply of safe, high quality water and efficient transport and treatment of wastewater." Utility Administration Division The Utility Administration Division provides the organizational leadership for the Utilities Department. This division is responsible for implementing the City Commission's utility policies. Utility Administration is the primary liaison between the Utility Department, the City administrative staff and elected officials, and other public and private organizations. The division is responsible for coordinating and facilitating the efforts of the other utility divisions, and Utility Administration is also responsible for long range planning and policy development. MAG/jm/Newserver/WordProc/1996/96-108,21/Report 8 04/12/01 II Utility Engineering Division The Utility Engineering Division provides technical support to the Utility Department. These services include design, review and approval of development plans; issuance of construction permits, providing construction inspection, as well as overseeing the optimization and rehabilitation of the water and wastewater systems. Water Plant Facility Division The Water Plant Facility Division operates and maintains the City owned Lime Softening Water Treatment Plant. The finished potable water quality meets applicable Federal and State Regulatory Agency primary drinking water requirements. Finished water is delivered at sufficient pressure levels for potable use and fire protection in the City's water distribution system. This division is also responsible for monitoring the potable water quality at the Water Plant Facility Division certified laboratory. Operations Division The Operations Division operates and maintains the City's 229.5 miles of water distribution and the 174 miles of wastewater collection and transmission system, which consists of 144 miles of gravity sewer lines, 74 pump stations, and 30 miles of transmission (force) mains. The division also performs miscellaneous construction required for the Utility Department to effectively and efficiently carry out its mission. The division is also responsible for reducing the amount of unaccounted for water usage and coordinates the repair of wastewater lines that have experienced infiltration /inflow. Support Services Division The Support Services Division provides required non -technical support services for the other divisions, including clerical, financial, purchasing and warehouse inventory. This division also provides water meter readings, billing, related customer service, and administers the City's Backflow Prevention Program. MAG/jm/New$erver/WordPr-/1996/96-108.21/Report 9 04/12/01 No Text 1 1 1 1.1 �11 SECTION 3 -ONGOING MAINTENANCE, RENEWAL I AND REPLACEMENT IMPROVEMENTS AND DEPRECIATION 1 SECTION 3 ONGOING MAINTENANCE, RENEWAL AND REPLACEMENT IMPROVEMENTS AND DEPRECIATION GENERAL The City of Tamarac recognizes the importance of maintaining and improving the operations of the Utility. The City also recognizes how important it is to maintain fixed assets. The City performs maintenance on all components of its utility systems. Maintenance is either conducted by in-house personnel or outside contractual services. Maintenance is classified as preventative maintenance or corrective service. Wastewater System Maintenance The City repairs thousands of feet of sewer main annually. A listing of maintenance performed on the wastewater system can be seen in Table 3-1. Table 3-1 Maintenance and Repairs on Wastewater System Fiscal Year 2000 Quantity Description Preventative (P) Corrective (C) ill Mechanical repairs at Pump Stations C 33 Motors pulled P 10 Motors sent out for electrical repairs C 22 Motors repaired in house C 355 Wet wells cleaned P 11 Pressure tests performed on Force Mains P 75 Off -hours emergency call -outs (Pump Stations) C 33 Force Main Valves Exercised P 2 Force Main Valve installed P MAO/jm/NewServer/WordPro&I996/96-108.21/Reports 11 4/12/01 Table 3-1 Continued Quantity Description Preventative (P) Corrective (C) 134 Electrical Repairs at Pump Stations C 2 Electrical Panel Upgrades (in-house) C 551 Manholes inspected P 6 Manhole Rehabs. C 1,477 Service Laterals inspected (from Main) P 98,785 Sanitary Main Inspected P 758 Main Line Joints grouted and sealed C 11,384 Sewer Main grouted and sealed C 114,719 Sewer Main cleaned C 0 Sewer Lines smoke tested P 86 Sewer Blockages C 54 Residential Mini -camera inspections (laterals) P 45 Emergency Call -outs (blockages, etc.) C 13 Clean -outs installed/repaired C 15 Sewer Wyes repaired/replaced C 40 Manhole Rainguards installed P 40 Contractor inspections (relining) C 8,839 Sewer Mains relined (contractors) C 6 Electronic Flow readings P Water System Maintenance The maintenance performed on the Water System can be divided into Water Treatment Facilities and Water Distribution system maintenance. Water treatment facilities maintenance. During the 2001 fiscal year, the city proposes to rehabilitate the two 2 MGD rectangular filters. Water distribution system maintenance. The City staff completed one thousand seven hundred seventy five (1,775) maintenance tasks in Fiscal Year 2000. A complete listing can be seen in Table 3-2. MAG/jm/NewServer/WordProc/1996/96-108.21/Reports 12 4/12/01 1 [7 1 1 L 1-1 Table 3-2 Maintenance and Repairs on Water Distribution Systems Fiscal Year 2000 Quantity Description Preventative (P) Corrective (C) 326 Service Line Repairs C 12 Water Main Repairs C 373 Yokes (boxed) P 25 New Service Lines P 620 Meters Relocated P 1,221 Meters Exchanged P 30 Valves Replaced C 1 New Valves Installed C 14 Fire Hydrants Replacement, C Appendix I lists maintenance performed in the preceding year. The City tracks unaccounted for water losses reporting less than 10% each year, the industry standard. Water distribution system maintenance is performed to reduce the amount of unaccounted for water. Renewal and Replacement Improvements and Other Improvements Telemetry system. The City of Tamarac is completing the design of a $1,570,000 telemetry system upgrade this year. The project is expected to be awarded in March 2001. The telemetry system's primary function will be to monitor wastewater pump stations and operate the water treatment facility on a 24 hour basis. ' Inflow and Infiltration. The Wastewater Capacity Analysis includes an Inflow and Infiltration Evaluation. Once identified, the locations with Inflow and Infiltration will be repaired. This is demonstrated by the $502,000 budgeted in each of the next 5 years. ' Wastewaters stem renewal and replacement. The City budgeted approximately $154 000 for renewing and upgrading existing Wastewater pump stations and force mains in Fiscal Year 2000. rWater treatment facilities renewal and replacement. The City budgeted $750,000 for design and construction of Water Treatment Facilities Renewal and Replacement projects MAG/jm/Newserver/WordProc/1996/96-108.21/Reports 13 4/12/01 11 + The City should continue to acknowledge unaccounted for water losses and should try to reduce them where possible. For example, continuing to replace galvanized steel service lines. Finally, the Utility's Operating Budget is shown in Table 3-3. Table 3-3 Utility Operating Budgets Operating Expenses FY 98 FY 99 FY 00 Utilities - Fund 425 31-01 Financial Advisor $4,910 $10,014 $2,500 31-03 Engineering Services 45,526 217,897 181,579 31-07 Project Management 23,385 13,432 4,813 34-00 Other Contract Services 7,247 14,962 22,160 34-01 Employment Agency Fees 15,866 17,948 22,847 34-02 Other Consultant Services 25,670 10,051 0 34-20 Water Purchased Resale 115,108 111,890 126,684 34-40 Wastewater Disposal 27787,491 2,577,599 2,580,047 40-01 Travel, Meals, Lodging 2,035 3,233 2,637 40-02 Seminars & Training 20,112 30,167 13,332 41-01 Telephone 21,974 9,781 13,218 41 -02 Wireless Phones & Pagers 0 1,117 3,440 41-10 Postage 890 77,797 86,221 43-01 Electricity 347,001 354,461 323,783 43-03 Water & Sewer 2,163 2,168 1,796 43-11 Sludge Removal 37,350 22,837 45,069 44-01 Rentals & Leases --- Copier 6,616 7,047 7,422 44-04 Equipment Rentals 0 2,503 5,208 46-01 R&M Office Equipment 1,399 1,687 1,072 46-02 R&M Service Contracts 2,938 21,040 23,626 46-04 R&M Facilities 32,179 13,220 17,596 46-06 R&M Gravity Sewer 4,541 1,255 1,647 46-07 R&M Water Mains 17,484 12,982 8,921 46-08 R&M Water Service Lines 25,048 20,619 13,773 46-09 R&M Street Repairs 3,577 1,906 3,986 46-10 R&M Other 7,590 1,438 2,135 MAG/jm/NewServer/WordProc/1996/96-108.21/Reports 15 04/12/01 1 1 1 1 1-1 Table 3-3 Continued Operating Expenses Continued FY 98 FY 99 FY 00 46-11 R&M Lift Stations & F/M 40,937 41,539 44,560 46-12 R&M Special Equipment 13 0 0 46-13 R&M Telemetry Eqpmnt 6,745 7,177 4,574 46-14 R & M Machinery 78,830 80,193 80,988 47-01 Printing - Other 9,483 15,729 20,473 49-04 Licenses & Permits 9,281 5,785 8,055 49-06 Water Testing 0 23,241 20,955 49-14 Debris Removal 0 0 8,328 49-15 Service Support 0 1,540 0 49-27 TAPP Incentive Program 0 0 27,330 49-31 Uncollectible 96,716 25,828 79482 51-00 Office Supplies 5,385 6,463 21,857 52-02 Gasoline/Diesel 2,105 3,517 5,310 52-04 Grease & Oil 338 396 332 52-05 First Aid Supplies 344 353 286 52-07 Supplies - Chemicals 251,406 218,721 212,063 52-08 Supplies -Software 15,971 33,944 1,624 52-09 Supplies - Computer 2,718 2,342 4,160 52-10 Supplies - Materials 8,492 13,422 22,769 52-11 Supplies - Paint 502 1,115 1,229 52-12 Photographic Supplies 1,055 744 655 52-13 Maps 761 42 0 52-14 Drafting 4,191 4,927 2,601 52-15 Equip Less Than $750 13,371 15,452 20,545 52-16 Supplies - Janitorial 472 111 0 52-17 Signs 2,111 1,104 1,434 52-18 Minor Tools 6,697 8,100 5,038 52-19 Barricades 2,648 316 1,812 52-20 Supplies - Other 24,303 23,772 22,580 52-21 Supplies - Safety 1,811 1,912 2,249 52-22 Landscaping & Irrigation 16,907 2,935 2,980 52-23 Supplies - Laboratory 16,077 16,830 17,796 52-24 Protective Clothing 10,489 13,141 10,683 I MAG/jm/NewServer/WordPror/1996196-108.21/Reports 16 04/12/01 1 fl 1 11 L,, 1 Table 3-3 Continued Operating Expenses Continued FY 98 FY 99 FY 00 52-25 Uniforms & Accessories 13,106 18,797 21,213 54-01 Books/Pubs/Subscriptions 2,801 2,279 2,814 54-02 Dues & Memberships 4,250 4,916 5,977 Personal Services 12-01 Regular Salaries 2,193,047 2,1.42,482 2,225,105 12-00 Less: Reimbursement 0 (6,546) (8,836) 14-01 Overtime 55,159 46,515 68,953 15-01 Longevity 26,715 18,691 22,067 15-04 Emergency Standby Pay 10,196 9,225 10,534 15-06 Comp Absences Payout 11,337 51,445 60,013 15-07 ERP Lump Sum Payout 40,847 0 0 21-00 FICA Taxes 180,084 173,525 182,574 22-01 Pension -- General 127,266 144,420 144,548 22-02 401(A)- Mgmt/Prof 32,244 48,181 50,691 23-01 Life Insurance 8,925 8,800 8,548 23-02 Health Insurance 178,391 203,259 215,774 23-03 Health Insurance Retiree 1,844 38,579 23,891 26-00 Benefit Option 86,532 90,575 95,634 27-01 Disability - Long Term 0 0 2,114 28-00 Dental Insurance 1,615 2,086 2,447 29-01 Automobile Allowance 3,600 3,600 2,700 Non -Operating Expenses 31-13 Planning Consultant 219,509 329,820 73,130 32-01 Auditing Services 18,440 21,625 27,250 49-05 Educational Assistance 0 0 113 49-40 Payment In Lieu of Taxes 519, 553 535,347 528,004 58-01 Information Services 280,742 320,360 332,970 58-02 Fleet Maint Charge 278,766 393,680 253,870 58-03 General Admin Service 1,557,540 1,604,270 1,636,355 58-04 Insurance Service Charge 494,472 362,817 76,390 59-00 Depreciation Expense 1,968,976 1,955,498 2,017,006 59-01 Amort-FA Abandon CST 74,026 74,026 74,026 59-02 Amort-System ACQ Costs 5,789 5,789 5,789 59-03 Amort-Bond Issue CSTS 38,662 37,245 35,861 I MAG/jm/NewServer/WordProc/1996/96-108.21/Reports 17 04/12/01 Ll n 1 �J 1 C 1 Table 3-3 Continued Non -Operating Expenses Continued FY 98 FY 99 FY 00 59-04 Amort-FA Abandon CST 7,372 7,372 7,372 59-05 Amort-Deferred Costs 68,837 65,127 61,504 63-04 Lift Station Rehabilitation 26,565 57,154 22,026 63-05 Meters & Meter Box 20,358 66,754 119,534 63-06 Backflow Preventers 2,944 896 704 63-09 Hydrants & Valve 0 26,362 26,738 63-10 Construction 17,390 0 0 63-20 Construction -Water Plant 0 24,284 0 63-30 Construction -Distribution 352,004 130,828 388,118 63-32 Cons -Service Line 0 0 15,538 63-40 Construction-WW 456,889 298,960 319,382 64-01 Equip. $500 or Greater 113,775 43,317 171,290 64-02 Office Furniture 2,465 4,358 1,654 64-03 Computer Equipment 93,417 55,851 20,563 64-04 Lab Equipment 5,745 1,579 5,300 64-05 Motor Vehicles 19,477 184,965 0 64-20 Telemetry Equipment 0 0 8,416 64-99 Fixed Assets - Contra Exp (1,078,748) (927,647) (1,175,501) 72-02 Interest - 1996 Rev. Bond 0 0 466,119 72-03 Interest - 1992 Rev. Bond 0 0 597,042 72-10 Notes Payable 0 3,757 2,911 73-01 Service Costs 0 0 3,314 91-06 Trf - Utility Bond Svc 1,022,820 967,820 0 91-07 Trf - Util Impry Replc 42,080 42,080 42,080 97-02 Contingency -Spec Proj 0 0 0 Total - Fund 425 13,796,440 13,824,864 13,397,888 Utilities Bond Service - Fund 426 71-02 Principal -1996 Rev. Bond 0 (100,000) 0 72-10 Principal -1992 Rev. Bond 0 100,000 0 72-02 Interest -1996 Rev. Bond 523,531 496,306 0 72-03 Interest -1992 Rev. Bond 655,280 627,230 0 73-01 Service Costs 3,039 3,247 0 Total - Fund 426 1,181,850 1,126,783 0 1 MAG/jm/NewServer/WordProe/1996196-108.21/Reports 18 04/12/01 1 1 1 1 1 1 fl 1 1 F Table 3-3 Continued Non -Operating Expenses Continued FY 98 FY 99 FY 00 Utilities C.I.A.C. - Fund 432 31-03 Engineering Services 35,323 182,613 80,829 31-07 Project Management 9,370 1,630 0 49-04 Licenses & Permits (899) 0 0 49-19 WW Resv Acq Chgs 0 0 1,877,999 63-30 Construction- Distribution 276,926 12,437 45,687 63-40 Construction-WW 0 773,760 0 64-99 Fixed Assets - Contra Exp (343,088) (916,773) (74,648) Total - Fund 432 (22,368) 53,667 1,929,867 ALL FUNDS TOTAL 14,955,922 15,005,314 15,327,755 91-06 Less Interfund Transfers (1,022,820) (967,820) 0 91-07 Less Interfund Transfers (42,080) (42,080) (42,080) GRAND TOTAL 13,891,022 13,995,414 15,285,675 ' MAG/jm/NewServer/WordPro4'/1996/96-108.21/RepoM 19 04/12/01 1 1 1 �11 1 1 1 I SECTION 4 -RATE SUFFICIENCY AND DEBT SERVICE COVERAGE 1 ' GENERAL 1 [l 1 SECTION 4 RATE SUFFICIENCY AND DEBT SERVICE COVERAGE The water and wastewater fund is classified as an enterprise fund and accounts for operations that are financed and operated in a manner similar to private business enterprises. As such, the intent and focus of the utility should be to ensure that the costs of providing goods or services to the general public on a continuing basis are financed or recovered primarily through user charges. This section includes a review of the sufficiency of the water and wastewater rates for fiscal year 2001 (FY 2001) for the City of Tamarac (the "City") and summarizes the results of the analyses and conclusions. The major objective considered in this analysis was the determination of the adequacy of rate revenue and/or existing reserves to meet the expenditure requirements of the utility systems in FY 2000. This is necessary in order to maintain the City's financial integrity as well as to continue to fund the capital needs of the system. In FY 1997, the City began the process of consolidating its two separate water and wastewater systems, previously referred to as Tamarac Utilities West (TUW) and Tamarac Utilities East (TUE), by adopting Resolution R-96-212, which consolidated the two systems from a legal, rate and accounting standpoint. This resolution established TUE rates as the same as the TUW rates, thus charging all City of Tamarac water and wastewater customers the same monthly rates. For FY 2000, Tamarac Utilities served an average of approximately 30,352 water accounts and 30,749 wastewater accounts. Rates and Charges After a comprehensive rate study, the City adopted new rates on September 25, 1996 under Resolution No. R-96-212. The purpose of the new rates was to meet the utility's fiscal requirements and to ensure adequate debt service coverage. Table 4-1 shows the current water rates, and Table 4-2 shows the current wastewater rates. Table 4-3 summarizes the miscellaneous service charges. These rates have remained unchanged since September 25, 1996, and are projected to remain effective for FY 2001. MAG/jm/NewServer/WordProc/1996/96-108.21/Reports 20 04/ 12/01 Table 4-1 Water Rates and Charges October 1, 2000 through September 30, 2001 Sinjzle Family Residential • Service Availability Charge Per Month All Meter Sizes $ 6.71 • Monthly Consumption Charge per 1,000 gallons 0 to 6,000 gallons $ 1.26 6,001 to 15,000 gallons $ 1.56 In excess of 15,000 gallons $ 1.86 Multiple_ Family Residential • Service Availability Charge per Unit per Month All Meter Sizes $ 4.68 • Monthly Consumption Charge per 1,000 gallons 0 to 6,000 gallons $ 1.26 In excess of 6,000 gallons $ 1.75 General Service or Commercial • Service Availability Charge per Month 5/8" $ 7.54 1" $ 18.89 11/2" $ 37.72 2" $ 60.35 3" $ 120.70 4" $ 188.58 6" $ 377.18 MAG/jm/Newserver/W ordProc/1996/96-108.21 /Reports 21 04/ 12/01 Table 4-1 Water Rates and Charges October 1, 2000 through September 30, 2001 (Continued) Monthly consumption charge per 1,000 gallons is based on meter size and two consumption blocks as follows: Rate Per 1,000 gallons Meter Size 5/8" 1" 1 1 /2" 2" 3" 4" 6" $1.26 $1.75 Block 1 (gallons per month) Block 2 (gallons per month) 0 - 6,000 0 - 15,000 0 - 30,000 0 - 48,000 0 - 96,000 0 - 150,000 0 - 300,000 Irrigation Service (all classes) — Water • Service Availability Charge Meter Size 5/8" 1" 1 1/2" 2" 3" 4" 6" • Monthly Consumption Charge per 1,000 gallons Fire Line Charges per year Meter Size 4" 6" 8" Over 8" Water CIAC per ERC In excess of 6,000 In excess of 15,000 In excess of 30,000 In excess of 48,000 In excess of 96,000 In excess of 150,000 In excess of 300,000 $ 7.54 18.89 37.72 60.35 120.70 188.58 377.18 $ 1.75 $ 432.60 865.20 1,555.30 By Agreement $ 1,400.00 MAG/jm/Newserver/WordProc/1996/96-108.21/Reports 22 04/ 12/01 Table 4-2 Wastewater Rates October 1, 2000 through September 30, 2001 Single Family Residential • Service Availability Charge Per Month All Meter Sizes $ 11.54 • Disposal Charge per 1,000 gallons of metered water usage (1) $ 2.48 Multiple Family Residential • Service Availability Charge per Unit per Month All Meter Sizes $ 7.67 • Disposal Charge per 1,000 gallons of metered water usage (1) $ 2.48 General Service or Commercial • Service Availability Charge per Month Meter Size 5/8" $ 14.82 1" $ 37.09 1 1 /2" $ 74.12 2" $ 118.59 3" $ 237.18 4" $ 370.59 6" $ 741.19 • Disposal Charge per 1,000 gallons of metered water usage $ 2.48 Dumpster • Service Availability Charge per Month $ 10.15 • Consumption Fee of $2.48 per 1,000 gallons based on 7,300 gallons discharge per month $ 18.10 Wastewater CIAC per ERC $ 1,800.00 Note: (1) No sewer disposal charge shall be imposed on water usage above 15,000 gallons per month per individual dwelling unit. MAG/jmMewServer/WordProc/1996/96-108.21/Reports 23 04/ 12/01 Table 4-3 Miscellaneous Service Charges October 1, 2000 through September 30, 2001 a Meter Installation Charges and Deposits: Meter Installation Meter Size Charge Deposit Residential 5/8" $ 160.00 $ 90.00 1" 230.00 235.00 1 1/2" 505.00 470.00 2" 590.00 745.00 Over 2" By Agreement By Agreement Commercial, Multiple -Family and General Service 5/8" $ 160.00 $ 105.00 1" 230.00 265.00 1 1/2" 505.00 530.00 2" 590.00 745.00 Over 2" By Agreement By Agreement Renters 5/8" $ 115.00 $ 180.00 1 " 225.00 470.00 1 1 /2" 400.00 650.00 2" 525.00 745.00 Over 2" By Agreement By Agreement Construction 5/8" $ 160.00 $ 105.00 Over 5/8" By Agreement By Agreement $50 for meter installation for each additional service call if meter cannot be installed first trip at no fault of the City. MAG/jm/NewServer/W ordProc/1996/96-108.21 /Reports 24 04/ 12/01 Table 4-3 Miscellaneous Service Charges October 1, 2000 through September 30, 2001 (Continued) • Meter Turn -on and Turn-off: During Normal Working Hours Meter Tum-on $ 20.00 Meter Turn-off $ 20.00 After Normal Working Hours $ 50.00 $ 45.00 • Reconnection After Discontinued Service for Cause of Non -Payment: During Normal Working Hours $ 30.00 After Normal Working Hours $ 60.00 • Returned Check Service Charge • Meter Re -reads and Special Reads • Testing of Water Meters: Meter Size 5/8" to V Over 1" $ 15.00 $ 15.00 Charge Per Test $ 35.00 Actual Cost • Dual Check Valve Installation Single Family Residential: Cost of dual check value plus 15% for administrative cost. * Back Flow Test Fee $40.00 per test plus Tamarac Building Department Plumbing permit fee. Water and Wastewater Customers (Accounts) and Billable Flows As mentioned above, the objective of this rate analysis was to determine the sufficiency of the water and wastewater rates and charges currently paid by the City's customers to recover the Utility's revenue requirements in FY 2001. In order to accomplish this, projections of customer statistics, such as the number of customer accounts billed by meter size and the amount of water MAG/jm/NewServerfWordProc/1996/96-108.21/Reports 25 04/ 12/01 and wastewater flow billed by the City, were developed. These projected customer statistics are based on historical and most recent available customer data. Table 4-4 and 4-5 summarize the projected number of customers and billable flow for fiscal year 2001, for water and wastewater, respectively. Table 4-5 Projected FY 2001 Water Customers and Billable Flow Average Customers Single Family Multiple Family Irrigation Commercial Total Average Customers Total Billable Water 15,188 994 16,182 13,256 0 13,256 442 4 446 756 26 771 29,631 1,024 30,654 (1,000s of Gallons) 2,106,820 48,144 2,154,964 Note: (1) The number shown is for dwelling units. Table 4-5 Projected FY 2001 Wastewater Customers and Billable Flow Average Customers Single Family Multiple Family Commercial Total Average Customers Total Billable Wastewater «r I • r I ♦ m Y 15,188 916 16,104 14,260 0 14,260 668 25 693 30,116 941 31,057 (1,000s of Gallons) 1,897,374 Note: (1) The number shown is for dwelling units. 42,908 1,940,282 MAG/jm/NewSer er/WordProc/1996/96-108.21/Reports 26 04/12/01 1 Projected FY 2001 Water and Wastewater Rate Revenue ' Based on the above projected FY 2001 average customers and billable flow and the application of current rates, the projected rate revenues in FY 2001 were developed. A breakdown of the ' projected rate revenues by customer class are summarized below in Table 4-6. Table 4-6 ' Projected FY 2001 Rate Revenue ' Water System Single Family $ 2,755,215 Multiple Family 1,678,913 Irrigation 380,718 Commercial 684,539 ' Total Water $ 5,498,885 ' Wastewater System Single Family $ 4,478,453 Multiple Family 3,195,574 ' Commercial 993,667 Total Wastewater $ 8,667,694 Total Water & Wastewater $ 14,166,579 ' Thus, as shown above, assuming the current water and wastewater rates are applied to all customers, it is projected that the total water rate revenue in FY 2001 would be approximately ' $5,500,000 while the total wastewater rate revenue would be approximately $8,670,000. I Rate Sufficiency Analysis and Debt Service Coverage for FY 2001 As discussed above, the primary objective of this rate analysis is to determine if the current rates ' and/or existing reserves will be sufficient to recover the utility's revenue requirements in FY 2001. In order to accomplish this, the City provided HAI with FY 2001 budgets for the water ' and wastewater systems. These operating and capital budgets, along with discussions with City staff, served as the basis for the rate analysis in FY 2001. These revenue requirements were then compared to the projected rate revenues generated by applying the current rates to all customers, as discussed previously, as well as revenue available from other sources such as miscellaneous 1 1 MAG/jm/NewServcr/WordProc/1996/96-108.21/Reports 27 04/ 12/01 11 service charges and interest income to determine the sufficiency of these rates. In addition, the availability of existing operating reserves was also considered in this analysis. The results of this analysis for the water and wastewater systems are summarized and presented in Table 4-7. Table 4.7 Projected FY 2001 Net Revenue Requirements from Rates Water Wastewater Total F-b•�,•.. - Sales Revenue (Existing Rates) $ 5,498,885 $ 8,667,694 $ 14,166,579 Other Operating Revenue 109,300 172,200 281,500 Interest Income 76,700 177,400 254,100 Total Available Revenue $ 5,684,885 $ 9,017,294 $ 14,702,179 Revenue Requirements Operating Expenses $ 4,357,226 Debt Service 446,469 Transfers 216,000 Capital Outlay From Rates 464,250 Total Revenue Requirements $ 5,483,945 Rate Revenue Surplus/(Deficiency) $ 200,940 Percent of Existing Rate Revenue 3.65% $ 6,399,874 1,785,876 324,000 154,750 $ 8,664,500 $ 352,794 4.07% $ 10,757,100 2,232,345 540,000 619,000 $ 14,148,445 $ 553,734 3.91% As shown above, the existing rates will be sufficient to cover the water and wastewater operating expenses, debt service, transfers, and capital outlay budgeted by the City to be funded from utility rates in FY 2001. Furthermore, other capital projects in the amount of $321,000 (not included in Table 4-7) are projected by the City to be funded from the CIAC Fund in FY 2001. The final rate sufficiency issue to be addressed is debt service coverage. The existing bond covenants require that coverage must be at least 1.10 (without CIAC fees). Based on the analysis provided herein, it is estimated that the debt service coverage ratio for FY 2001 will be approximately 1.77 as shown below in Table 4-8. MAG/jm/NewServer/WordProc/1996/96-108.21/Reports 28 04/ 12/01 tTable 4-8 Projected FY 2001 Debt Service Coverage ' Projected Revenues (1) $ 14,702,179 ' Projected Operating Expenses (10,757,100) Projected Net Revenues $ 3,945,079 Debt Service - FY 2001 $ 2,232,345 Debt Service Coverage Ratio 1.77 Requirement 1.10 Note: (1) Includes sales revenues, other operating revenues and interest ' income. Conclusions and Recommendations To summarize the above analyses, the following conclusions were made: • In FY 2001, the utility is projected to meet its fiscal requirements without any water and wastewater rate adjustments. ' • The utility is projected to meet its debt service coverage requirements in FY 2001, based on the assumptions discussed herein. ' • The City currently uses the "pay as you go" method of funding capital improvement projects. This may not be the most cost effective or appropriate method in the future. The City should strongly consider the possibility of fully funding its water and wastewater capital improvement program through the issuance of additional revenue bonds. Not only are the interest rates currently favorable, but this could also ease the burden on existing customers and help the utility to maintain reasonable reserves. Another potential benefit of a bond issue is to structure the additional debt service in such ' a way to levelize the utility's debt service in the future and maintain stable water and wastewater rates. MAG/jm/NewServer/Worffroc/1996/96-108.21/Repom 29 04/ 12/01 Based on the above, it is recommended that: • Water and wastewater rate adjustments are not needed in fiscal year 2001. The utility continues to examine and refine its long-term capital improvement program. • The utility considers alternative funding mechanisms for its capital needs other than depletion of existing reserves in order to mitigate potential rate adjustments in the future. MAG/jm/NewServer/WordProc/1996/96-108.21/Reports 30 04/ 12/01 1 u 1 1 1 1-1 1 APPENDIX 1 City of Tamarac Utilities Department Maintenance Record/ Schedule Equipment Task Due Date Water Treatment Plant 1998 1999 2000 4 MGD Accelerator Lubricate Drive 10/16 Q Q Accelerator Drive Motor Check Motor/Electrical 8/16 Q Q Air Cond. No.l Fan Motor Check Motor/Electrical 6/19 A A Air Cond. No.2 Fan Motor Check Motor/Electrical 6/19 A A Back -Up Scott Air Packs Open & Check SCBAA M M Backwash Pump No. 1 Motor Check Motor/Electrical 9/14 Q Q Backwash Pump No. 2 Motor Check Motor/Electrical 5/20 Q Q Backwash Pump No. 1 Grease Fittings Q Q Backwash Pump No. 2 Grease Bearings 7/22 Q Q Backwash Valve Motor Check Motor/Electrical 7/22 Q CL2 Building Sump Motor Check Motor/Electrical 8/16 Q Q CL2 Control Building Exhaust Check Motor/Electrical 5/18 Q Q CL2 Exhaust Blower Motor Check Motor/Electrical 8/16 1/4 Q Coag. Blower Motor Check Motor/Electrical 8/11 Q Q Coag. Feed Motor Check Motor/Electrical 8/11 Q Q Coag. Mixer Motor Check Motor/Electrical 8/11 Q Q E. 8 MGD Accelerator Change Oil- Drive Unit 11/1 A A E. 8 MGD Accelerator Motor Check Motor/Electrical 10/16 Q Q E. 8 Mgd Oil Pump Motor Check Motor/Electrical 5/24 Q Q Exhaust Blower Motors Check Motor/Electrical SA SA Exhaust Fan — Fluoride Room Check Motor/Electrical 5/20 SA SA Exhaust Fan — Motor Check Motor/Electrical 4/28 SA SA Fluoride Pump Motor Check Motor/Electrical 5/20 Q Q Generator -- WTP Clean & Check Gen Set W W Greenleaf Sump Motor Check Motor/Electrical Q Q Greenleaf Vac No. 1 Electrical Check 7/19 Q Q Greenleaf Vac No.2 Electrical Check 7/19 Q Q Grit Conveyor Motor No. 1 Check Motor/Electrical 5/20 Q Q Grit Conveyor Motor No. 2 Check Motor/Electrical 5/20 Q Q High service No. 1 Motor Grease Motor Bearings 9/14 Q Q . 1 Legend W — weekly M — monthly Q — quarterly SA — semi-annually A — annually MAG/jm/NewServer/WOTdProc/1996/96-108.21 /Reports 04/ 12/01 City of Tamarac Utilities Department Maintenance Record/ Schedule Equipment Task Due Date Water Treatment Plant Cont'd. 1998 1999 2000 High service No. 2 Motor Grease Motor Bearings 9/14 Q Q High service No. 3 Motor Change Oil — Motor 9/14 Q Q High service No. 4 Motor Change Motor Oil 10/6 Q Q High service No. 5 Motor Grease Motor Bearings 5/25 Q Q High service No. 6 Motor Grease Fittings 5/25 Q Q High service No. 7 Motor Grease All Fittings 7/13 Q Q High service No. 1 Motor Check Motor/Electrical 4/26 Q Q High service No. 2 Motor Check Motor/Electrical 4/26 Q Q High service No. 3 Motor Check Motor/Electrical 4/26 Q Q High service No. 4 Motor Check Motor/Electrical 3/29 Q Q High service No. 5 Motor Check Motor/Electrical 5/23 Q Q High service No. 6 Motor Check Motor/Electrical 5/23 Q Q High service No. 7 Motor Check Motor/Electrical 5/23 Q Q Hoist Clean Tracks for Hoist 8/22 SA SA Lime Slurry Pot — N Slake Check Drive Belts 7/26 Q Q Lime Slurry Pot — S Slake Check Drive Belts 7/13 Q Q Manual Filter No. 1 Grease Valve Boxes 5/12 A A Manual Filter No. 2 Grease Valve Boxes 5/12 A A Manual Filter No. 3 Grease Valve Boxes 5/12 A A Manual Filter No. 4 Grease Valve Boxes 5/12 A A Manual Filter No. 5 Grease Valve Boxes 5/12 A A Manual Filter No. 6 Grease Valve Boxes 10/17 A A Motorola UPS Order Batteries 4/04 N. Lime Slaker Change Gear Box Oil 7/04 SA SA Polymer Pump Motor No. 1 Check Motor/Electrical 5/20 Q Q Polymer Pump Motor No. 2 Check Motor/Electrical 5/20 Q Q Pump No. 1 Recovery Pond Check Motor/Electrical 8/11 Q Q Pump No. 2 Recovery Pond Check Motor/Electrical 8/11 Q Q Pump Room Exhaust Fan Electrical Check 4/30 SA SA ii Legend W -- weekly M — monthly Q — quarterly SA — semi-annually A — annually MAG/jm/NewServer/WordProc/1996/96-108.21/Repor s 04/12/01 City of Tamarac Utilities Department Maintenance Record/ Schedule Equipment Task Due Date Water Treatment Plant Cont'd. 1998 1999 2000 S. Lime Slaker Change Gear Box Oil 10/16 SA SA Scott Air — Pack (East) Open & Check SCBA M M Scott Air — Pack (West) Open & Check SCBA M M Shop Air Comp. Motor Check Motor/Electrical 3/22 Q Q Silo Air Compressor Mtr Check Motor/Electrical 5/19 Q Q Slaker Air Compressor Change Oil 6/04 M M Slaker Drive Motor No. 1 — S Check Motor/Electrical 5/20 Q Q Slaker Drive Motor No. 2 — N Check Motor/Electrical 5/20 Q Q Slaker Feeder Belt Mtr Check Motor/Electrical 5/20 Q Q Slurry Pot Mixer Motor Check Motor/Electrical 5/20 Q Q Slurry Pot Mixer Motor Check Motor/Electrical 5/20 Q Q Transfer Pump No. 1 Motor Check Motor/Electrical 3/29 Q Q Transfer Pump No. 1 Check Lubrication 6/16 Q Q Transfer Pump No. 2 Motor Check Motor/Electrical 3/29 Q Q Transfer Pump No. 2 Check Lubrication 6/16 Q Q Vacuum Pump Motors Check Motor/Electrical 4/23 Q Q W 8 MGD Drive Motor Check Motor/Electrical 4/26 Q Q W 8 MGD Oil Pump Motor Check Motor/Electrical 5/24 Q Q W 8 MGD Accelerator Check Lubrication 5/24 Q Q W 8 MGD Accelerator Motor Check Motor/Electrical 4/27 Q Q WTP Fluoride System Clean Fluoride Room Q WTP Fuel Containment Clean out debris, Etc. Q WTP Vehicles Inspect Vehicles W WTP — CL2 Equipment Check CL2 Equipment W iii Legend W — weekly M — monthly Q — quarterly SA — semi-annually A — annually MAG/jrn NewServer/WordProc/1996/96-108.21/Reports 04/12/01 City of Tamarac Utilities Department Maintenance Record/ Schedule Equipment Task Due Date Water Distribution 1998 1999 2000 Generator - Grants Clean & Check Gen Set W W Generator — T27 Clean & Check Gen Setr W W GP — Fuel Containment Clean out containment Grants No. 1 Pump Grease Motor Bearings 6/19 Q Q Grants Pump No. 1 Motor Check Motor/Electrical Q Q Grants No. 2 Pump Grease Motor Bearings 7/15 Q Q Grants Pump No. 2 Motor Check Motor/Electrical Q Q Grants — CL2 Equipment Check CL2 Equipment W T27 Pump No. 1 Motor Grease Bearings Q Q T27 Pump No. 2 Motor Grease Motor Bearings Q Q T27 Pump No. 3 Motor Grease Motor Bearings Q Q Tract 27 CL2 Equipment Check CL2 Equipment W Tract 27 Scott Air — Pack Open & Check SCBA M M Waste -Water Collection/Transmission See Section 3 Raw Water Wells Well No. 01 Grease Motor 10/6 All Maintenance Performed Quarterly Well No. 01 Pump Motor Check Motor/Electrical 5/20 Well No. 02 Grease Bearings 10/7 Q Well No. 03 Grease Bearings 10/21 Q Well No. 03 Pump Motor Check Motor/Electrical 5/20 Q Well No. 04 Grease Motor 10/7 Q Well No. 04 Pump Motor Check Motor/Electrical 8/18 Q Well No. 05 Grease Motor Bearings 10/21 Q Well No. 05 Pump Motor Check Motor/Electrical 8/18 Q Well No. 06 Grease Motor Bearings 10/21 Q IV Legend W — weekly M — monthly Q — quarterly SA — semi-annually A — annually MAG/jm/NewServer/WordProc/1996/96-108,21/Reports 04/ 12/01 City of Tamarac Utilities Department Maintenance Record/ Schedule Equipment Task Due Date Raw Water Wells Cont'd. 1998 1999 2000 Well No. 06 Pump Motor Check Motor/Electrical 8/18 Q Well No. 07 Grease Motor Bearings 10/7 Q Well No. 07 Pump Motor Check Motor/Electrical 9/20 Q Well No. 08 Grease Motor Bearings 10/7 All Maintenance Performed Quarterly Well No. 08 Pump Motor Check Motor/Electrical 9/20 Well No. 09 Grease Motor Bearings 9/9 Q Well No. 09 Pump Motor Check Motor/Electrical 8/19 Q Well No. 10 Clean Sump Pump Pit 7/14 Q Well No. 10 Exhaust Motor Check Motor/Electrical 8/10 Q Well No. 10 Pump Motor Check Motor/Electrical 8/10 Q Well No. 10 Sump Motor Check Motor/Electrical 4/26 Q Well No. 11 Paint Well Lids 7/14 A Well No. 11 Pump Motor Check Motor/Electrical 8/10 Q Well No. 11 Sump Motor Check Motor/Electrical 4/26 Q Well No. 12 Clean Sump Pump Pit 7/14 Q Well No. 12 Exhaust Motor Check Motor/Electrical 8/10 Q Well No. 12 Pump Motor Check Motor/Electrical 8/10 Q Well No. 12 Sump Motor Check Motor/Electrical 8/17 Q Well No. 13 Clean Sump Pump Pit 7/14 Q Well No. 13 Exhaust Motor Check Motor/Electrical 8/10 Q Well No. 13 Pump Motor Check Motor/Electrical 8/10 Q Well No. 13 Sump Motor Check Motor/Electrical 8/15 Q Well No. 14 Grease Motor Bearings 10/21 All Maintenance Performed Quarterly Well No. 14 Pump Motor Check Motor/Electrical 8/11 Well No. 15 Grease Motor Bearings 10/21 Q Well No. 15 Pump Motor Check Motor/Electrical 8/11 Q Well No. 16 Greast Motor Bearings 10/21 Q Well No. 16 Pump Motor Check Motor/Electrical 8/11 Q v Legend W — weekly M — monthly Q — quarterly SA — semi-annually A — annually MAG/jm/NewServer/WordProc/1996/96-108.21 /Reports 04/ 12/01 City of Tamarac Utilities Department Maintenance Record/ Schedule Equipment Task Due Date Raw Water Wells Cont'd. 1998 1999 12000 Well No. 17 Grease Motor Bearings 10/21 All Maintenance Performed Quarterly Well No. 17 Pump Motor Check Motor/Electrical 8/11 Well No. 18 Pump Motor Check Motor/Electrical Q Well No. 18 Check Motor Bearings 7/21 Q Well No. 19 Check Motor/Electrical 7/21 Q Well No. 19 Grease Motor Bearings Q vi Legend W -- weekly M — monthly Q — quarterly SA — semi-annually A — annually MAG/jm/NewServerAVordProc/1996/96-108.21 /Reports 04/ 12/01